Guardian
7, 12 & 15 kW Generators
- Quiet,
powerful OHVI single-cylinder or V-Twin engines fueled
by natural gas or LP gas.
- UL
Listed remote-mounted pre-wired automatic transfer switch
with 8, 10 or 12 circuit emergency load center for fast
and efficient unattended transfer to generator when utility
power fails.
- A
standard weather protective enclosure with sound-absorbing
panels protects generator from harmful weather and also
reduces exterior noise levels. Includes key locks for
security.
- Hinged
top and removable front panel for easy serviceability.
- Built-in
charger maintains battery at optimum performance level.
- Automatic
safety shutdowns protect engine and generator in event
of low oil pressure, high temperature, overspeed and/or
overcrank.
- Automatic
seven-day exerciser runs the system for twelve minutes
weekly to maintain top running condition.
- Installation
system includes the pre-wired automatic transfer switch
with built-in load center, 30' and 2' wiring harnesses,
pre-wired external connection box, 1' flexible fuel line,
"Do-It-Yourself" installation guide and a composite mounting
pad.
Generator
Set
| Model
Number |
04389 |
04456 |
04390 |
| Rated
Power LP (kW) |
7 |
12 |
15** |
| Rated
Power NG (kW) |
6 |
12 |
13 |
| Voltage
@ 60 Hz |
120/240 |
120/240 |
120/240 |
| Phase |
Single |
Single |
Single |
| Frequency |
60
Hz |
60
Hz |
60
Hz |
| Amps
LP |
58.3/29.2 |
100.0/50.0 |
125.0/62.5 |
| Amps
NG |
50.0/25.0 |
100.0/50.0 |
108.3/54.2 |
| Engine/Alternator
RPM |
3600/3600 |
3600/3600 |
3600/3600 |
| Engine |
410
cc.
14.5 HP
Generac OHVI
Single Cylinder |
992
cc.
30 HP
Generac OHVI
V-Twin |
992
cc.
30 HP
Generac OHVI
V-Twin |
| EPA/CARB
Certified |
Yes |
Yes |
Yes |
| Fuel |
Natural
Gas/
LP Vapor |
Natural
Gas/
LP Vapor |
Natural
Gas/
LP Vapor |
| Engine
Cooling |
Air |
Air |
Air |
| UL2200 |
Yes |
Yes |
Yes |
| Canadian
UL |
Yes |
Yes |
Yes |
| Main
Line Circuit Breaker |
40
Amp |
50
Amp |
60
Amp |
| Dimensions
(L" x W" x H") |
48
x 24 x 28-1/4 |
48
x 24 x 28-1/4 |
48
x 24 x 28-1/4 |
| Unit
Wt. (lbs.) |
452 |
470 |
487 |
Controls
| Start/Stop
Control |
Cyclic
cranking: 7 seconds on, 7 seconds rest. 90 seconds
overcrank protection. |
| Automatic
Low Oil Shutdown |
Standard |
| Overspeed
Shutdown |
Standard,
72 Hz |
| Overcrank
Protection |
Standard |
| Automatic
Voltage Regulator with Over-Voltage Protection |
Standard |
| Engine
Warmup |
10
seconds |
| Engine
Cool-Down |
1
minute |
| Safety
Fuse |
Standard |
| Starter
Lockout |
Starter
cannot re-engage until 5 seconds after the engine
has stopped |
| 2
Amp Timed Trickle Battery Charger |
Standard |
| Auto
Switch |
Utility
failure/7 day exercise |
| Off
Switch |
Stops
unit. Power is removed. Control and charger still
operate |
| Manual
/ test |
Start
with starter control, unit stays on. If utility fails,transfer
to load takes place |
back
to top |
 |